<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/ http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
  <dc:creator>Theologou, Thomas</dc:creator>
  <dc:creator>Clivio, Sara</dc:creator>
  <dc:creator>Younes, Adel</dc:creator>
  <dc:creator>Demertzis, Stefanos</dc:creator>
  <dc:creator>Ferrari, Enrico</dc:creator>
  <dc:date>2022</dc:date>
  <dc:description xmlns:ns0="xml" ns0:lang="en">Redo aortic valve surgery for the failure of a previously implanted valve is always challenging. In case of small-sized implanted valves, the use of a balloon-expanding Sapien-3 valve can enhance the final effective orifice area, avoid annulus enlargement complex techniques, and can reduce operative time and morbidities. We describe a case where after explanting a failed 19 mm St. Jude mechanical aortic valve and further deployment of a 23 mm Sapien-3 valve, the left coronary ostia was obstructed by the skirt of the transcatheter prosthesis. After careful removal of a little part of the skirt, we were able to restore the coronary flow and the patient had a favorable outcome.</dc:description>
  <dc:format>application/pdf</dc:format>
  <dc:identifier>https://susi.usi.ch/global/documents/325693</dc:identifier>
  <dc:identifier>https://localhost:5000/ark:/12658/srd1325693</dc:identifier>
  <dc:identifier>https://susi.usi.ch/documents/325693/files/Theologou_2022_Wiley_jcs.pdf</dc:identifier>
  <dc:language>eng</dc:language>
  <dc:relation>info:eu-repo/semantics/altIdentifier/doi/10.1111/jocs.16462</dc:relation>
  <dc:relation>info:eu-repo/semantics/altIdentifier/ark/12658/srd1325693</dc:relation>
  <dc:rights>info:eu-repo/semantics/openAccess</dc:rights>
  <dc:rights>CC BY</dc:rights>
  <dc:source>Journal of cardiac surgery. - 2022, vol. 37, no. 6, p. 1740-1742</dc:source>
  <dc:subject xmlns:ns1="xml" ns1:lang="en">Redo aortic valve surgery</dc:subject>
  <dc:subject xmlns:ns2="xml" ns2:lang="en">Sapien‐3 valve</dc:subject>
  <dc:subject xmlns:ns3="xml" ns3:lang="en">Transcatheter aortic valve</dc:subject>
  <dc:subject>info:eu-repo/classification/udc/61</dc:subject>
  <dc:title xmlns:ns4="xml" ns4:lang="en">The use of balloon-expandable Sapien-3 valve in redo aortic valve replacement and the potential risk of left main stem occlusion</dc:title>
  <dc:type>http://purl.org/coar/resource_type/c_6501</dc:type>
</oai_dc:dc>
